GW Instek PEL-503-80-50 - 250W 80V/50A Programmable DC Load
Overview
Features
Specifications
Calibration
The PEL-500 series single-channel electronic load has a total of 5 models and provides 0~80V/ 0~500V voltage operating ranges and 250~700W power operating range. The series can be applied to R&D, quality control, ATE system and production test, including voltage source/current source test; switching power supply transient response; constant voltage mode for current limiting test; battery simulation; and battery discharge test.
- 5-digit digital voltage, current and power meter
- Simultaneous display of voltage, current, and watts
- Short-circuit time can be set during short-circuit test
- Automatic test function of overcurrent protection/overpower protection
- The battery discharge test function can set the discharge stop voltage (Vbatt), discharge capacity (AH, WH) and stop discharge time.
- Surge test can simulate boot overshoot current and transient current from hot plugging.
- Constant current, constant resistance, constant voltage, constant power and Dynamic mode
- Overvoltage, overcurrent, over power, over temperature protection and reverse polarity detection
- Voltage polarity display can be set to positive value ("+") or negative value ("-")
- Communications interface: RS232, USB
Input Ratings
Power(Watt) | 250 W |
Current(Ampere) | 50 A |
Voltage(Volt) | 80 V |
Min. Operating Voltage | 1.0V @ 50A |
Protections
Over Power Protection(OPP) | ≒262.5W |
Over Current Protection(OCP) | ≒52.5A |
Over Voltage Protection(OVP) | ≒84V |
Over Temp. Protection(OTP) | YES |
CC Mode
Range | 0~5.04~50.4A |
Resolution | 0.084mA/0.84mA |
Accuracy | ±0.1% of (SETTING + RANGE) |
CR Mode
Range | 0.016~1.6~96000Ω |
Resolution | 26.666µΩ /0.010416mSiemens |
Accuracy | ±0.2% of (SETTING + RANGE) |
CV Mode
Range | 0~8.1~81V |
Resolution | 0.135mV/1.35mV |
Accuracy | ±0.05% of (SETTING + RANGE) |
CP Mode
Range | 0~25.02~250.2W (Imax=r1:5A, r2:50A) |
Resolution | 0.417mW/4.17mW |
Accuracy | ±0.5% of (SETTING + RANGE) |
Dynamic Mode
THIGH/TLOW | 10µS to 9.999 Sec |
Resolution | 0.001/0.01/0.1/1mS |
Slew rate (L) | 0.032~2A/µs |
Slew rate (H) | 3.2~200mA/µs |
Accuracy | ±5%±10µs |
Measurement
Voltage Read Back |
| ||||||||
Current Read Back |
| ||||||||
Power Read Back |
|
Surge Test
Surge & Normal current | 0~50A |
Surge time | 10~1000ms |
Surge step | 1~5 |
Battery Discharge Test
UVP | 0~81V |
Time | 1~99999 Sec |
Capacity | 0.1~19999.9AH/0.1~19999.9WH |
Other
Load ON Voltage | 0.1~25V |
Accuracy | 1% of (SETTING + RANGE) |
Load OFF Voltage | 0~25V |
Accuracy | 0.05% of (SETTING + RANGE) |
Imonitor (Non-isolated) | 5.04 A/V |
Current Monitor | Full scale: 10V |
Accuracy | 0.5% of (SETTING+ RANGE) |
Typical Short Resistance | 0.018Ω |
Max. short Current | 50A |
Power input | 115/230 Vac±10%, 50/60Hz |
Interface (Standard) | USB/RS232 |
Power Consumption | 40 VA |
Dimension (HxWxD) | 205 x 123 x 477mm |
Weight | 5.3kg |
Do you have a 250W 80V/50A Programmable DC Load that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 250W 80V/50A Programmable DC Load calibrated today! Click Here!