Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

APM SPST300VAC9000W-4-17 - Linked 3-Phase AC Power Supply System

Linked 3-Phase AC Power Supply System

APM

Rated 0 / 5 (0 reviews)

Category : AC/DC and AC Source

add to cart

Documents:
Datasheet Application Guide USB Driver DSP firmware upgrade tool for AC source AC Waveform Simulation Panel AC Waveform Simulation Panel Operation Manual Labview Driver (GPIB) Labview Driver (LAN) Labview Driver(USB) Labview Driver (RS232/RS485)

Pricing displayed is for budgetary planning only. Please call us at (905) 660-3797 or click on "add to cart" for a formal competitive quotation

Overview
Features
Specifications
Calibration

It is a 3-phase output programmable AC power supply which provides with high power density. With high speed DSP+CPLD control, high frequency PWM technology, active PFC design, It is able to provide not only stable DC/AC output power, but also 3-phase / 1-phase output. It is featured with high power density, high reliability and high precision, meanwhile it possesses operation interface of touch screen and keys manually. It is able to analog output normal or abnormal power input for electrical device to meet test requirements, which is applicable to electric, lighting, aviation sectors, etc. It could be applied to enterprise’s production test as well.

 

Basic Function:

Adjustable Phase Angle/Slope

Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.

 

High Output Current Factor

The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.

 

Output Simulation Sequence and Disturbance Simulation

Capable of simulating power line disturbance simulation test.

 

Built-in IEC Standard Test

Built-in IEC standard test could be recalled directly

  • Large touch color screen, possess complete functions and easy to operate
  • AC+DC mixed or independent output mode for voltage DC offset simulation
  • Capable of setting output slope/phase angle, 0~359.9°
  • Output frequency 15~1000Hz, capable of setting output slope of voltage and frequency
  • High output crest factor could satisfy surge tests requirements
  • Multiple current measuring level selection. Increase measurement accuracy
  • Standard USB data interface, support CSV file waveform import
  • OCP/OVP/OPP/OTP/ Short circuit protection
  • Built-in power meter, which is capable of measuring 15 electrical parameters per phase, including voltage, current, power, etc
  • With reverse current protection to avoid current flowing backward
  • Capable of setting voltage and current output restriction, support for constant current output mode

 

Input

Voltage190~265VAC
Frequency47~63Hz
Phase3 Phase, 4Wire + Ground / Y Connect
Max. Current60A
Power Factor at 220VAC Input,Full Load≥ 0.98 Active PFC
Efficiency>86% (Peak)
>85% at 220VAC, 50Hz
input/230VAC, 50Hz output
Full Load

 

3-Phase Output Mode (Per Phase)

AC Power(Total)9000VA
AC Power(Per Phase)3000VA
Max.Current (r.m.s)
0~150V(L)27.6A
0~300V(H)13.8A
Max.Current (Peak)
0~150V(L)165.6A
0~300V(H)82.8A

 

1-Phase Output Mode

AC Power(Total)[1]8100VA
Max.Current (r.m.s)
0~150V(L)74.52A
0~300V(H)37.26A
Max.Current (Peak)
0~150V(L)447.12A
0~300V(H)223.56A
DC Power (Per Phase)8100W
Max.Current (Total)
L52.92A
H26.46A

 

3-Phase Output Mode(Per Phase)

Total Harmonic Distortion (THD)<0.5% (Resistive Load) at 15.0~70.0Hz and output voltage within the 80~140VAC at Low Range or the 160~280VAC at High Range;
<1% (Resistive Load) at 70.1~500Hz and output voltage within the 80~140VAC at Low Range or the 160~280VAC at High Range;
<1% (Resistive Load) at 501~1000Hz and output voltage within the 100~140VACat Low Range or the 160~280VAC at High Rang;
Crest Factor(CF)≤6
Load Regulation±0.2%F.S. (Resistive Load) at 15~100Hz
±0.5%F.S. (Resistive Load) at >100Hz
Line Regulation± 0.1V
Voltage(AC) (L-N)
Range0~300VAC, 150V/300V/Auto Mode
Resolution0.1V
Accuracy0.2% of setting +0.4%F.S at Voltage>3V
Phase Angle (Starting /Ending)
Range0~359.9°
Resolution0.1°
Accuracy± 1° @45~65Hz
Range0~424VDC
Voltage(DC)
Resolution0.1V
Accuracy0.3% of setting +0.4%F.S at Voltage>3V
DC Power3000W
Max.Current
L19.6A
H9.8A
Ripple&Noise(Peak)L <700mVrms @Bandwidth 20Hz to 1MHz
H <1100mVrms @Bandwidth 20Hz to 1MHz
Ripple&Noise(r.m.s)<4000mVp-p @Bandwidth 20Hz to 1MHz
Current OC Fold Mode
Resolution0.01A
Accuracy2.0% of setting +1.0%F.S.
Response Time<1400ms
Frequency
Range15~1000Hz
Resolution0.1Hz(15.0~99.9Hz),1Hz(100~1000Hz)
Accuracy0.03% of setting
Programmable Output ImpedanceNot Support
Harmonic & Interharmonics SimulationNot Support

 

Power Meter Function(Per Phase)

Voltage
Range
AC 0~300VAC
DC0~424VDC
Resolution0.1V
Accuracy0.2% of setting +0.4%F.S. (Peak: 0.6% of setting +1%F.S.)
Frequency
Range15~1000Hz
Resolution0.1Hz(15.0~99.9Hz),1Hz(100~1000Hz)
Accuracy0.1% of setting
Current[2] (r.m.s)
Range
H0.3A~27.6A
L0.1A~5A
M0.2A~20A
mA0.02A~1.5A
Resolution0.01A
Accuracy0.4%+1.0%F.S.
Current[2] (Peak)
Range0A~168.6A
Resolution0.01A
Accuracy0.4%+1.5%F.S.
Power
Range0~3060W
Resolution0.1W
Accuracy0.4% of setting +0.3%F.S. at PF>0.2, Voltage >5V
Power Apparent(VA)
Range0~3060VA
Resolution0.1VA
AccuracyVoltage*Irms, Calculated value
Power Resistive (VAR)
Range0~3060VAR
Resolution0.1VAR
Accuracy√((VA)2-(W)2), Calculated Value
Power Factor (PF)
Range0.00~1.00
Resolution0.01
AccuracyW/VA, Calculated value
Harmonic
RangeNot Support

 

Extra Function

Slew Rate
Range
AC Voltage0.001~1200.000V/ms and Disable
DC Voltage0.001~1000.000V/ms and Disable
Frequency0.001~1600.000Hz/ms and Disable
Remote Sense
Range5V(rms), Max. Total power less than rated power
CalibrationFirmware-based calibration through the digital interface or front panel display
Test FunctionNot Support
Graphic Display4.3'' Color touch LCD
Operation Key FeatureSoft key, Numberic key, Rotary Knob, USB port for transfer and upgrading firmware
Rack mount HandlesYes
FANTemperature Control
Protection CircuitsOCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP
InterfaceUSB, RS485, RS232, LAN(Option); GPIB(Option)

 

Environmental

Operating Temperature0°C~40°C
Storage Temperature-40°C~85°C
Altitude2000m
Relative Humidity5%~95%, non-condensing
Temperature Coefficient100ppm/°C at Voltage, 300ppm/°C at Current,100ppm/°C at Frequency

 

Mechanical

Dimensions(WxHxD)560.0 x 754.0 x 700.0 mm
Package Dimensions (WxHxD)680.0 x 1146.0 x 820.0 mm
Unit Weight157.0kg
Shipping Weight195.0kg

 

Regulatory Compliance

CE MarkInstallation Overvoltage Category II;Class II equipment;indoor use only.

[1] In single phase mode, the current shall be reduced to 90% for the consideration of current sharing.
[2] The tolerance will change slightly in high frequency condition;
All specifications are subject to change without notice.


Do you have a Linked 3-Phase AC Power Supply System that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Linked 3-Phase AC Power Supply System calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the APM SPST300VAC9000W-4-17 - Linked 3-Phase AC Power Supply System

Linked 3-Phase AC Power Supply System

Name :

Email :

Title :

Review: