This series Programmable DC electronic load provides three voltage ranges 200V/600V/1200V. Supports CV, CC, CR, and CP these 4 basic operating modes, as well as CV+CC, CV+CR, CR+CC these 3 complex operating modes. Full protection including OCP, OPP, OTP, over-voltage and reverse alarm. Support external control and monitor mode, the 0 to 10V input or output signal represent 0 to full range voltage or current. Provide OCP test, OPP test, and Short circuit simulation to effectively solve the application demands for power and automated testing. Built-in RS232, RS485, and USB communication interfaces, LAN&GPIB communication card is optional. Two or more loads can be connected in master-slave parallel mode to provide more power or current capacity. This series DC load can be applied to battery discharge, DC charging station, and power electronics, and other electronics products.

 

Color Touch Screen

This series programmable DC electronic load together with a large color touch screen provides simple and fast operation for customers. Real-time update of display input data, status, and graphical display make it more intuitive.

 

Multiple Operating Modes

This series programmable DC electronic load provides four kinds of basic operating modes including CV (constant voltage), CC (constant current), CR (constant resistance), CP (constant power), to satisfy a wide range of test requirements.

 

Adjustable CV Loop Speed

This series electronic load supports CV loop response speed setting to VerySlow, Slow, Normal, Fast, and very fast to satisfy different test requirements. This function may avoid the inaccurate measurement or testing fail caused by the response speed mismatch between the load and the power supply, which is possible to improve test efficiency and reduce costs on the equipment, time, and expenses.

 

Dynamic Load

This series of electronic loads can be switched quickly between different values in the same operating mode, including CC dynamic mode, CV dynamic mode, CR dynamic mode, and CP dynamic mode, CC/CR high-speed dynamic mode up to 50kHz. This function is suitable for the transient test of power supply, a test of battery protection characteristic and battery pulse charging, etc. Dynamic mode test has a continuous mode, pulse mode, and toggle mode.

 

Sine Wave Dynamic Load

This series of electronic loads support sine wave loading function which allows loading sine wave, can be used for impedance analysis test of fuel cells.

 

Dynamic Frequency Sweep Function

This series electronic load provides a unique constant current dynamic sweep to use frequency conversion to find out the UUT voltage of the worst case. This CC dynamic sweep allows the user to edit two load levels, start frequency, end frequency, step frequency, dwell, etc. The sampling rate is up to 500kHz, which make it can simulate different loading conditions for most test requirements.

 

Battery Discharge Test

This series electronic load has a battery discharge function and can perform discharge test under CC, CR, or CP mode. The DC load can set end voltage or time to stop loading correctly and make sure the battery is not damaged due to over-discharge. The user can set stop conditions, whenever met any condition, the load will stop loading and counting automatically. During the test, users can observe the battery's voltage, discharging time, and already-discharged-capacity.

 

Auto Mode

This mode allows automatically switches among CV, CR, CC, and CP modes. It is suitable for lithium-ion battery charger testing to get a complete V-I charging curve. This flexible auto mode also enormously improve test efficiency.

 

OCP/OPP Tests

This series of electronic loads provides OCP and OPP modes are mainly applied in over-current and over-power point tests. After the testing, the load can automatically judge the test result according to the set specifications. Take OPP testing as an example, the OPP provides ramped up power for the load to test the UUT voltage whether has reached trigger voltage level and to judge if the protection is acting normally or not.

 

List Mode

The list function allows users to create waveform files to automatically simulate various complicated loading conditions. The list mode has 10 files, by editing operating mode (including CC, CV, CR, CP, Short and ON/OFF), repeat times, total steps, setting the value of each step and step time, etc. This function can be applied to the testing of output characteristics and stability for power supply.

 

Master/Slave Control

This series electronic load provides the user with a Master/slave mode that supports parallel connection under different power and the same voltage and dynamically synchronized. In Master/slave mode, the user only needs to control the master one, the load current will be automatically calculated and downloaded to the slave loads. The Master/slave mode greatly simplifies the operation when increased power is needed.

 

External Control and Current/Voltage Monitoring

This series electronic load has an analog control interface to control the input voltage and current. The external signal 0 to 10V controls the sinking condition from 0 to full scale. Using the external control mode can simulate arbitrary waveform which is ideal for industrial control requirements. The 0 to 10V analog output signal of V-MON/I-MON terminals represent input to which the terminals belong from 0 to full range. An external voltmeter or oscilloscope can be connected to display input voltage/current change.

 

Difference between Advanced Version and Professional Version

Description Single Unit(Professional Version) Single Unit (Advanced Unit)
Dynamic Frequency Sweep Function Supported Not supported
Sine Wave Dynamic Load Supported Not supported
High-Speed Sampling Rate Supported Not supported
Non-Linear Load Supported Not supported
User-Defined Waveform Supported Not supported
MPPT Supported Not supported
External Waveform Control Supported supported
Parallel 20pcs 20pcs

 

  •  A Color touch screen allows convenient access and operation
  • Provides four kinds of basic working mode such as CV/CC/CR/CP, and CV+CC/CV+CR/CR+CC complex operating modes
  • Adjustable current slew rate, adjustable CV loop speed
  • Ultra high precision voltage & current measurement
  • OCP/OPP testing function
  • 50kHz high-speed CC/CR dynamic mode
  • 500kHz high-speed voltage and current sampling rate
  • Timing & discharging measurement for batteries
  • Short circuit test mode
  • Auto mode function provides an easy way to do a complicated test
  • Dynamic frequency sweep function for determining worst-case voltage peaks*
  • Non-linear load mode function makes the simulated loading current more realistic*
  • Supports external analog control function
  • V-monitor/I-monitor
  • LED load simulation function
  • Full protection: OCP, OPP, OTP, over-voltage and reverse alarm
  • Up to 20 units master/slave parallel control
  • Front-panel USB interface supports data import and export
  • SCPI language and standard rack size make it ideal for ATE System integration
  • Smart fan control with lower noise and better for the environment
  • Multi versions to meet the cost performance and different applications

* Only professional Electronic Load units support these functions

 

General

Voltage0~200V
Current0~190A
Power0~1800W
Graphic Display4.3” Color touch LCD
Operation Key FeatureSoft key, Numeric key, Rotary Knob, USB port for transfer and upgrading firmware
Rack Mount HandlesYes
FANTemperature Control
InterfaceRS232/RS485/USB(Standard), GPIB/LAN(Optional)
Communication Response Time30ms
Storage CapacityUser defined settings (300 sets), OCP settings (10 sets), OPP settings (10 sets), Default settings (1 set), Factory setting (1 set)

 

Min. Operating Voltage : 0.18V@19A

Static Mode
Constant Current Mode
Range0~19A
Resolution0.1mA
Accuracy0.05%+0.05%F.S.
Constant Voltage Mode
Range0~16V
Resolution0.1mV
Accuracy0.025%+0.025%F.S.
Constant Power Mode
Range0~180W
Resolution10mW
Accuracy0.2%+0.2%F.S.
Constant Resistance Mode
Range20mΩ~200Ω(16V)
Resolution20mΩ(16V)
AccuracyVin/Rset*(0.2%)+0.2% IF.S.
Dynamic Mode (CCD/CRD)
T1&T2(Pro.)0.02ms~300s
T1&T2(Adv.)0.05ms~300s
Resolution1μs
Accuracy1μs+100ppm
Slew Rate(Pro.)0.1mA/μs~1.9A/μs
Slew Rate(Adv.)0.1mA/μs~0.19A/μs
Min. Rise Time(Pro.)10μs(Typical)
Min. Rise Time(Adv.)50μs(Typical)
Resolution0.1mA/μs
Accuracy5%±10us
Measurement
Voltage
Range0~16V
Resolution0.1mV
Accuracy0.015%+0.015%F.S.
Current
Range0~19A
Resolution0.1mA
Accuracy0.04%+0.04%F.S.
Power
Range0~180W
Resolution10mW
Accuracy0.1%+0.1%F.S.
Sampling Frequency500kHz
Protection
OVP17.6V
OCP19.38A
OPP185.4W
Over Temperature70-75°C
Overvoltage Safety Value110%VF.S.
Reverse AlarmYes
Alarm ToneYes

 

Min. Operating Voltage : 0.9V@95A

Static Mode
Constant Current Mode
Range0~95A
Resolution0.5mA
Accuracy0.05%+0.05%F.S.
Constant Voltage Mode
Range0~80V
Resolution0.5mV
Accuracy0.025%+0.025%F.S.
Constant Power Mode
Range0~900W
Resolution50mW
Accuracy0.2%+0.2%F.S.
Constant Resistance Mode
Range80mΩ~800Ω(80V)
Resolution80mΩ(80V)
AccuracyVin/Rset*(0.2%)+0.2% IF.S.
Dynamic Mode (CCD/CRD)
T1&T2(Pro.)0.02ms~300s
T1&T2(Adv.)0.05ms~300s
Resolution1μs
Accuracy1μs+100ppm
Slew Rate(Pro.)0.5mA/μs~6.65A/μs
Slew Rate(Adv.)0.5mA/μs~0.95A/μs
Min. Rise Time(Pro.)10μs(Typical)
Min. Rise Time(Adv.)50μs(Typical)
Resolution0.5mA/μs
Accuracy5%±10us
Measurement
Voltage
Range0~80V
Resolution0.5mV
Accuracy0.015%+0.015%F.S.
Current
Range0~95A
Resolution0.5mA
Accuracy0.04%+0.04%F.S.
Power
Range0~900W
Resolution50mW
Accuracy0.1%+0.1%F.S.
Sampling Frequency500kHz
Protection
OVP88V
OCP96.9A
OPP927W
Over Temperature70-75°C
Overvoltage Safety Value110%VF.S.
Reverse AlarmYes
Alarm ToneYes

 

Min. Operating Voltage : 1.8V@190A

Static Mode
Constant Current Mode
Range0~190A
Resolution2mA
Accuracy0.05%+0.05%F.S.
Constant Voltage Mode
Range0~200V
Resolution2mV
Accuracy0.025%+0.025%F.S.
Constant Power Mode
Range0~1800W
Resolution100mW
Accuracy0.2%+0.2%F.S.
Constant Resistance Mode
Range 2000mΩ~4000Ω(200V)
Resolution2000mΩ(200V)
AccuracyVin/Rset*(0.2%)+0.2% IF.S.
Dynamic Mode (CCD/CRD)
T1&T2(Pro.)0.02ms~300s
T1&T2(Adv.)0.05ms~300s
Resolution1μs
Accuracy1μs+100ppm
Slew Rate(Pro.)2mA/μs~13.3A/μs
Slew Rate(Adv.)2mA/μs~1.9A/μs
Min. Rise Time(Pro.)10μs(Typical)
Min. Rise Time(Adv.)50μs(Typical)
Resolution2mA/μs
Accuracy5%±10us
Measurement
Voltage
Range0~200V
Resolution2mV
Accuracy0.015%+0.015%F.S.
Current
Range0~190A
Resolution2mA
Accuracy0.04%+0.04%F.S.
Power
Range0~1800W
Resolution100mW
Accuracy0.1%+0.1%F.S.
Sampling Frequency500kHz
Protection
OVP220V
OCP193.8A
OPP1854W
Over Temperature70-75°C
Overvoltage Safety Value110%VF.S.
Reverse AlarmYes
Alarm ToneYes

 

Mechanical

Dimensions (WxHxD)423.0 x 88.0 x 610.0mm
Package Dimensions (WxHxD)665.0 x 333.0 x 918.0mm
Unit Weight22kg
Shipping Weight31kg

 

AC Input

Voltage100~240Vac
Frequency50~60Hz
Power150VA
Fuse2.5A

 

Non-Linear Mode

Range
CL30uF~50000uF
RLAs CR Mode
Ls0.1uH~16uH
Rs30mΩ~20Ω
Resolution
CL1uF
RLAs CR Mode
Ls0.1uH
Rs1mΩ

 

Battery Discharge Mode

Battery VoltageAs CV Mode
Current ResolutionAs CC Mode
RecordAH/WH
Test Time1s~100000s
Time Resolution1s

 

Program Mode

Step No.300 Max.
Dwell0.1ms~4000s
Spec CheckVoltage/Current/Power

 

External Waveform Control/Monitor

Control/MonitorVoltage/Current
Input/Ouput Range0~10V
Voltage Range
0.18V@19A0~L_range F.S.
0.9V@95A0~M_range F.S.
1.8V@190A0~H_range F.S.
Current Range
0.18V@19A0~L_range F.S.
0.9V@95A0~M_range F.S.
1.8V@190A0~H_range F.S.

 

Short Circuit

Current(CC)Full range current value
Voltage(CV)Voltage value at the Max power in working mode
Resistance(CR)Min resistance value of CR Mode

 

Master/Slave

Parallel InterfaceRJ45
Parallel Quantity (Pro.)20 units
Parallel Quantity (Adv.)10 units

 

Environmental

Operating Temperature0~40°C
Storage Temperature-20~80°C
Temperature Coefficient100ppm/°C(Typical)
Relative Humidity10~90%RH
Altitude<2000m

 

Regulatory Compliance

Overvoltage CategoryII
Protection DegreeI
Pollution DegreeII
Input Impedance800kΩ(Typical)
Isolation Voltage/
CertificatesCE

Do you have a Middle Power DC Electronic Load (Advanced) that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Middle Power DC Electronic Load (Advanced) calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the APM EL200VDC1800W - Middle Power DC Electronic Load (Advanced)

Middle Power DC Electronic Load (Advanced)

Name :

Email :

Title :

Review: