APM SP300VAC4000W Professional - 4000W Switching Mode Single-Channel Output High-Precision Programmable AC Power Source
This Product includes the following certification: CE/CSA/UL/FCC
SP300VAC4000W is a switching mode single-channel output high-precision programmable AC power source, which adopts high speed DSP+CPLD control, high frequency PWM power technology and active PFC design to realize AC/DC stable output. SP300VAC4000W is featured with high power density, high reliability and high precision, meanwhile it possesses operation interface of touch screen and keys manually. It is able to analog output normal or abnormal input for electrical device to meet test requirements.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Basic Functions:
- Adjustable Phase Angle/Slope
Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.
Adjustable Phase Angle
Adjustable Slope -
High Output Current Crest Factor
The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
-
Transient mode
Transient mode simulates the impact on test object when turn on or turn off transient high power capacity load in power grid.
Voltage Spikes
Voltage Sags -
Dimmer Function
Support Dimmer function, which is applicable to conduct speed regulating or dimming verification test for electric motor, lamp and other products.
-
Output Simulation Sequence and Disturbance Simulation
Capable of simulating power line disturbance simulation test.
LIST Mode
STEP Mode
PULSE Mode -
Advanced Functions:
-
Output Impedance(Applicable to Professional Version)
Support Simulating Output Impedance
-
Built-in IEC Standard Test(Applicable to Professional Version)
Built-in IEC standard test could be recalled directly.
-
Amplifier Function
The programmable AC power source could realize real time output by tail after signal waveform.
-
Harmonics/ Inter-harmonics Generate Simulation and Measurement(Applicable to Professional Version)
Up to 40 orders of harmonics components, applicable to interference simulation test.
-
External Control Function
Programmable AC power sources could provide analog input under test simulation of PASS, FALL and RUN status and user can control ON/OFF externally, force to shutdown, reset and upload 7 sets of stored parameters. -
3-Phase Operation and Parallel Mode
Support up to 2 units in series, 4 units in parallel and 3 units combined to 3-phase power output.
-
Outline dimensions drawing:
outline dimension(W*H*D)=483.0 mm x 177.0 mm x 520.0 mm
- 5.6’’ large touch color screen, possess complete functions and easy to operate.
- Support for USB data import/export and screen snap from front panel.
- AC+DC mixed or independent output mode for voltage DC offset simulation.
- Capable of setting voltage and current output restriction, support for constant current output mode.
- Capable of setting output slope of voltage and frequency.
- Capable of setting ON/OFF phase angle.
- Support for LIST/PLUSE/STEP mode, simple time setting and circulation setting, which is suitable for power line disturbance simulation test.
- Built-in power sweeping function.
- Built-in Transient mode.
- Built-in Dimmer function.
- With reverse current protection to avoid current flowing backward.
- Built-in power meter, which is capable of measuring 15 electrical parameters, including voltage, current, frequency, etc.
- Support mA current measurement function.
- Built-in IEC61000-3-3/ IEC61000-3-2/ IEC61000-4-11/ IEC61000-4-14/ IEC61000-4-28/ IEC61000-4-13 standard test required waveform.
- Support up to 2 units in series, 4 units in parallel and 3 units combined to 3-phase power output (optional).
Voltage | 190~265VAC |
Frequency | 47~63Hz |
Phase | 1 Phase, 2Wire+Groud |
Max. Current | 25A |
Power Factor at 220VAC Input, Full Load |
≥0.99 Active PFC |
Efficiency | >87% (Peak) >86% at 220VAC,50Hz input/220VAC,50Hz output, Full Load |
Output
AC Power | 4000VA |
Max. Current (r.m.s) 0~150V(L) | 32A |
Max. Current (r.m.s) 0~300V(H) | 16A |
Max. Current (Peak) 0~150V(L) | 160A |
Max. Current (Peak) 0~300V(H) | 80A |
Phase | 1 Phase |
Crest Factor(CF) | ≤5 |
Load Regulation | ±0.1V |
Line Regulation | ±(1% of output + 1V) |
Voltage(AC) Range | 0~300VAC, 150V/300V/Auto Mode |
Voltage(AC) Resolution | 0.1V |
Voltage(AC) Accuracy | 0.2% of setting +0.2%F.S. |
Voltage(DC) Range | 0~424VDC |
Voltage(DC) Resolution | 0.1V |
Voltage(DC) Accuracy | 0.2% of setting +0.2%F.S. |
Voltage(DC) Max. Power | 4000W |
Voltage(DC) Max. Current | L 22.6A |
Voltage(DC) (L/H Range) | H 11.3A |
Current OC Fold Mode Resolution | 0.01A |
Current OC Fold Mode Accuracy | 2.0% of setting +0.1%F.S. |
Current OC Fold Mode Response Time | <1400ms |
Frequency Range | 15~1200Hz Full Range ADJ |
Frequency Resolution | 0.1Hz at 15.0~99.9Hz, 1Hz at 100~1000Hz, 5Hz at 1001~1200Hz |
Frequency Accuracy | 0.03% of setting |
Programmable Output Impedance Range | 0Ω +200µH~1Ω +1mH |
Harmonic & Inter- harmonics Simulation Range | 2400Hz |
Measurement
Voltage Range | AC 0~300VAC DC 0~424VDC |
Voltage Resolution | 0.1V |
Voltage Accuracy | 0.2% of setting +0.2%F.S. |
Frequency Range | 15~1200Hz |
Frequency Resolution | 0.1Hz at 15.0~99.9Hz, 1Hz at 100~1000Hz, 5Hz at 1001~1200Hz |
Frequency Accuracy | 0.1% of setting |
Current (r.m.s) Range | H 0.2A~32A M 0.15A~20A L 0.1A~5A mA 0.02A~1.5A |
Current (r.m.s) Resolution | 0.01A |
Current (r.m.s) Accuracy | H/M 0.4%+0.3%F.S. L/mA 0.4%+1.0%F.S. |
Current (Peak) Range | 0.05A~163A |
Current (Peak) Resolution | 0.01A |
Current (Peak) Accuracy | H/M 0.4%+0.6%F.S. L/mA 0.4%+1.0%F.S. |
Power Range | 0~4080W |
Power Resolution | 0.1W |
Power Accuracy | 0.4% of setting +0.3%F.S. at PF>0.2, Voltage >5V |
Harmonic Range | 2~40 orders |
General
Parallel Output for 1 Phase | Yes, 4 Units Max. (Option: Remote O/P & Parallel, Multiphase Link Card) |
Series Output for 1 Phase | Yes, 2 Units Max. (Option: Remote O/P & Parallel, Multiphase Link Card) |
Link Output for 3 Phase | Yes (Option: Remote O/P &Parallel, Multiphase Link Card) |
FAN | Temperature Control |
Protection Circuits | OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP |
Interface | USB, RS485, RS232,LAN(Standard); GPIB (Optional) |
Environmental
Operating Temperature | 0°C to 40°C |
Storage Temperature | -40°C to 85°C |
Altitude | 2000m |
Relative Humidity | 5%~95%, non-condensing |
Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at Frequency |
Mechanical
Dimensions(W*H*D) | 483.0*177.0*520.0mm |
Unit Net Weight | 28.8kg |
Do you have a 4000W Switching Mode Single-Channel Output High-Precision Programmable AC Power Source that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 4000W Switching Mode Single-Channel Output High-Precision Programmable AC Power Source calibrated today! Click Here!
There are currently no reviews for this product.