AMPROBE AMP-320 - 600 A AC/DC Clamp Meter Electrical Motor Maintenance
Overview
Features
Specifications
Calibration
The Modern Evolution of the Professional Clamp Meter
Amprobe's AMP-300 Series True-RMS Clamp Meters offer a complete range of measuring functions for modern industrial environments, motor testing and HVAC applications. All models feature True-RMS sensing, low pass filters and fast response processors for quick, error-free measurements. The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, and a third input jack enables motor rotation and 3-phase sequence testing.
AMPROBE AMP-320 - 600 A AC/DC Clamp Meter Electrical Motor Maintenance- True-RMS
- HVAC Features
- Temperature measurement; User selectable °F or °C
- DC Microamps for flame sensor testing
- Capacitance measurement for start and run motor capacitors
- Amp-Tip Function
- Low Pass Filter for variable frequency drives
- Safety Rated: CAT III 600 V
AMP-300 Series Applications
- Accurate measurement of current, voltage and frequency on all electrical systems including distorted, non-sinusoidal signals (True-RMS function) and variable frequency drives (low pass filter).
- Capacitance measurement for start and run motor capacitors.
- Resistance and continuity functions to verify quality of electrical connections and to check if motor and transformer coils are working properly.
- 3-phase Motor and Phase Rotation Tests allow proper connection of a motor to a 3-phase system. Improperly connected motors will spin in a reverse direction, which may destroy the motor or equipment connected to it.
- Low Pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency). Without this feature, the meter would provide erroneous readings when measuring voltage and current.
- DC Microamps output for measurement of flame sensors. Test the proper operation of the flame sensor safety system in gas appliances. A broken sensor in a gas appliance will prevent the safety valve from opening and the appliance will not work.
- Inrush current measurement for motor start-up monitoring, allowing users to verify that the motor is receiving the required inrush current to support proper motor start.
Detailed Specifications
Safety Rating | CAT III 600 V |
Jaw Opening | 1.37 in (35 mm) |
AC Voltage (True-RMS) | Range: 0 to 600.0 V Accuracy: ±1.0% + 5LSD (50 to 60 Hz) |
DC Voltage | Range: 0 to 600.0 V Accuracy: ±1.0% + 5LSD |
AC+DC Voltage | Range: 0 to 600.0 V Accuracy: 1.2% ± 7LSD (DC, 50 to 60 Hz) |
AC Current (True-RMS) | Range: 0 to 600.0 A Accuracy: ±1.8% + 5LSD (50 to 100 Hz) ±2.0% + 5LSD (100 to 400 Hz) |
DC Current | Range: 0 to 600.0 A Accuracy: ±2.0% + 5LSD |
AC+DC Current | Range: 0 to 600.0 A Accuracy: ±2.2% + 7LSD (DC, 50 to 100 Hz) ±2.7% + 7LSD (100 to 400 Hz) |
Precise Low Current AC | Range: 0 to 60.00 A Accuracy: ±1.5% + 5LSD (50 to 60 Hz) |
Precise Low Current DC | Range: 0 to 60.00 A Accuracy: ±2.0% + 5LSD |
Precise Low Current AC+DC | Range: 0 to 60.00 A Accuracy: ±2.0% + 5LSD (DC, 50 to 60 Hz) |
Frequency | Range: 5.00 to 999.9 Hz Accuracy: ±1.0% + 5LSD (600 V range) Range: 50.0 to 400.0 Hz Accuracy: ±1.0% + 5LSD (600 A range) |
Resistance | Range: 0.0 to 60.00 kΩ Accuracy: ±1.0% + 5LSD |
Capacitance | Range: 0.0 to 2500 μF Accuracy: ±2.0% + 4LSD |
Continuity Beeper | ON ≤ 10 Ω OFF > 250 Ω |
Non-Contact Voltage | 20 to 440 V, 50/60 Hz 20 to 440 V, 50/60 Hz |
True-RMS | ![]() |
Low Pass Filter | ![]() |
Autoranging | ![]() |
Relative Zero | ![]() |
MAX/MIN/AVG | ![]() |
Diode Test | ![]() |
Data Hold | ![]() |
Backlight | ![]() |
Auto Power Off | ![]() |
DC Microamps | Range: 0.0 to 2000 μA Accuracy: ±1.0% + 5LSD |
Temperature* (Type K thermocouple) *Error does not include Type-K thermocouple errors |
Range: -40.0 to 752°F, -40.0 to 400°C Accuracy: -40.0 to 14.0°F (±1.0% +3.0°F), >14.0 to 99.9°F (±1.0% +1.5°F) 100 to 752°F (±1.0% +2°F), -40.0 to -10.0°C (±1.0% +1.5°C) >-10.0 to 99.9°C (±1.0% +0.8°C), 100 to 400°C (±1.0% + 1°C) |
3-Phase and Motor Rotation Indication |
Rotation-R for mains supply Rotation-M for motors |
Inrush Current |
![]() |
Peak Hold (Crest) |
- |
Work Light |
- |
General Specifications
Display | 3-5/6 digits 6000 counts |
Polarity | Automatic |
Update Rate | 5 per second nominal |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Relative Humidity | 80% at 30°C, 50% at 40°C |
Operating Altitude | 0 to 2000 m |
Pollution Degree | 2 |
Storage Temperature | -4 to 140°F (-20°C to 60°C),< 80% RH |
Temperature Coefficient | Nominal 0.15 x (specified accuracy)/ °C @ (0°C to 18°C or 28°C to 40°C) |
Battery | Two AAA 1.5 V battery |
EMC | Meets EN 61326-1:2006 |
Safety Compliance | UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 |
Certification | UL (c/us) and CE |
Dimensions (L x W x H): | 8.82 x 3.03 x 1.46 in (224 x 77 x 37 mm) |
Weight: | 254 g (0.56 lb) |
Do you have a 600 A AC/DC Clamp Meter Electrical Motor Maintenance that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 600 A AC/DC Clamp Meter Electrical Motor Maintenance calibrated today! Click Here!
There are currently no reviews for this product.