Fluke FETI125/C3I-30HZ - CNXTM Ti125 with Three i00 iFlex Clamp Modules

 CNXTM Ti125 with Three i00 iFlex Clamp Modules

Fluke

Category : Infrared Thermometers / Cameras

by quote only Add to Cart

Documents:

Overview
Features
Information
Calibration

Capture three True RMS current measurements in hard to reach places on your next infrared inspection with the Fluke CNX Ti125 iFlex® kit. The i3000 iFlex® modules allow you to measure around tight, awkward spaces and/ or sizes and makes wire access easier. You can then view your current measurement results on the Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to three critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!

 

Get all the information you need to quickly troubleshoot problems with the Fluke CNX Ti125 Industrial Kit.

The Ti125 Offers:

  • IR-Fusion® with AutoBlend- blends a digital and partially transparent IR image into a single image, making problem detection fast and easy.
  • Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
  • IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
  • Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
  • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).

The CNX i3000 iFlex® AC Wireless Current Module Offers:

  • True-rms AC current measurements to 2500 A
  • 3% accuracy
  • Memory recording up to 65,000 readings
  • iFlex current probe allows you to get into tight, awkward spaces
  • Backlit LCD display
  • CAT III 1000, CAT IV 600 V
  • IP42

 

Fluke Ti125 Infrared Camera

Detailed Specifications
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 μm to 14 μm (long wave)
Capture or refresh rate 9 Hz or 30 Hz versions
NETD (thermal sensitivity) ≤ 0.10 °C at 30 °C target temp (100 mK) 
 0.10 °C at 30 °C target temp (100 mK)
FOV (field of view) 22.5 °H x 31 °V
IFOV (spatial resolution) 3.39 mRad
Temperature measurement range (not calibrated below -10  °C) -20 °C to +350 °C (-4 °F to +662 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex™ focus system
IR-Fusion® technology PIP, FULL IR, FULL VISIBLE, AutoBlend™
CNX wireless enabled Yes
Color alarms High temperature, low temperature, isotherm
Standard palettes Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Ultra Contrast™ palettes Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Hot/cold markers Yes
User definable spot markers Three on camera and in SmartView®
Centerbox (MIN/AVG/MAX) Yes
Level and span control Manual and auto
Minimum span in auto mode 5 °C
Minimum span in manual mode 2.5 °C
Minimum IR focus distance 15.25 cm (6 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade
Minimum automatic parallax correction ~18-22 inches
IR-PhotoNotes™ annotation system Yes (3 images)
Laser pointer Yes
Torch Yes
Electronic (cardinal) compass Yes
Emissivity correction Yes
Transmission correction Yes
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output Streaming USB video output (infrared, visible and IR-Fusion modes)
Multi-mode video recording (standard avi w/ mpeg encoding) Yes (AVI with MPEG encoding, up to 5 minutes)
Multi-mode video recording (radiometric .Is3) Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
Memory review Thumbnail review
Battery (field-replaceable, rechargeable) Two
Battery life 4+ hours (each)*
External battery charging base Yes
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Recommended calibration cycle Two-years
Multifunction card reader Included
Memory storage 2 GB SD memory card
Direct download capability Mini USB download direct to PC
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes

*Assumes 50% brightness of LCD

Fluke CNX i3000 iFlex AC Wireless Current Module

Specifications
Range 2500 A AC
Resolution 0.1A to 999.9, 1A from 1000 to 2500
Accuracy 3 % ± 5 digits
Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display 3-1/2 digits,  LCD w/backlight
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory record up to 65,000 readings
Unbound listen interval 5 seconds
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree 2
Temperature coefficient Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm
  (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Jaw opening 25.4 cm (10 in) coil

Do you have a CNXTM Ti125 with Three i00 iFlex Clamp Modules that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your CNXTM Ti125 with Three i00 iFlex Clamp Modules calibrated today! Click Here!