The Fluke 1623 and 1625 are distinctive earth ground testers that can perform all four types of earth ground measurement. Specifically, the Fluke 1623 and 1625 testers are able to measure earth ground loop resistances using only clamps – called Stakeless testing. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods.
Testing Methods
- 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes
- Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.
- Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.
The Fluke 1625 offers these advanced features
- Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.
- R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see.
- Adjustable limits – for quick test result verification.
- One-button measurement concept
- 3- and 4-pole earth ground measurement
- 4-pole soil resistivity testing
- Selective testing, no disconnection of ground conductor (1 clamp)
- Stakeless testing, quick ground loop testing (2 clamps)
- Measuring frequency 128 Hz
RA 3-pole ground resistance measurement (IEC 1557-5) | |||||
Measuring Voltage |
|
||||
Short circuit current |
|
||||
Measure frequency |
|
||||
Resolution |
|
||||
Measuring range |
|
||||
Intrinsic error |
|
||||
Operating error |
|
RA 4-pole ground resistance measurement (IEC 1557-5) | |||||
Measuring Voltage |
|
||||
Short circuit current |
|
||||
Measure frequency |
|
||||
Resolution |
|
||||
Measuring range |
|
||||
Intrinsic error |
|
||||
Operating error |
|
RA 3-pole ground resistance measurement with current clamp | |||||
Measuring Voltage |
|
||||
Short circuit current |
|
||||
Measure frequency |
|
||||
Resolution |
|
||||
Measuring range |
|
||||
Intrinsic error |
|
||||
Operating error |
|
RA 4-pole selective ground resistance measurement with current clamp | |||||
Measuring Voltage |
|
||||
Short circuit current |
|
||||
Measure frequency |
|
||||
Resolution |
|
||||
Measuring range |
|
||||
Intrinsic error |
|
||||
Operating error |
|
Stakeless ground loop measurement | |||||||
Measuring Voltage |
|
||||||
Measure frequency |
|
||||||
Noise current (Iext) |
|
||||||
Resolution |
|
||||||
Measuring range |
|
||||||
Intrinsic error |
|
||||||
Operating error |
|
Environmental Specifications | |||||
Working temperature |
|
||||
Operating Temperature |
|
||||
Nominal temperature |
|
||||
Storage Temperature |
|
||||
Climatic class |
|
||||
Protection type |
|
Safety Specifications | |||
Safety Rating |
|
Mechanical & General Specifications | |||||||
Display |
|
||||||
Size |
|
||||||
Weight |
|
||||||
Warranty |
|
||||||
Battery Life |
|
Do you have a Basic Geo Earth Ground Tester Kit that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Basic Geo Earth Ground Tester Kit calibrated today! Click Here!